Meter ECH2O 5TE

Soil moisture, temperature, and electrical conductivity

The 5TE monitors bulk electrical conductivity (EC), in addition to volumetric water content (VWC) and soil temperature.

Monitor salt levels

The 5TE enables users to measure the EC response to salts and fertilizers in the soil. EC Measurements require good contact between the stainless steel electrodes on the sensor, and the soil. In potting soil and soilless medias, we recommend using the GS3 to maintian good soil contact and compensate for air gaps in the substrate.

Engineered for accuracy

The 5TE determines VWC by measuring the dielectric constant of the media using capacitance/frequency domain technology. The sensor uses a 70 MHz frequency, which minimizes salinity and textural effects, making the 5TE accurate in most soils. The 5TE measures temperature with an onboard thermistor, and electrical conductivity using a stainless steel electrode array. VWC in mineral soils is calculated using the Topp equation; other calibrations are provided on request. Temperature and electrical conductivity are factory calibrated for all soil types.

Easy installation

The 5TE’s small size makes it easy to install in the field and the greenhouse. This robust sensor should be pushed directly into undisturbed soil to ensure good accuracy.

Easy integration

Each 5TE comes standard with serial and SDI-12 communication options, meaning easy integration with systems manufactured by other companies.

Advantages of the 5TE

  • Measures VWC, EC, and temperature
  • Monitoring salts
  • SDI-12 compatible
FEATURES
  • Three measurements in one
  • Plug and play capability
  • Use with the EM60G to collect data remotely
  • Easy installation
  • 70 MHz frequency minimizes salinity and textural effects
  • Measures VWC, EC, and temperature
  • Salt-monitoring capabilities
  • SDI-12 compatible
SPECIFICATIONS
Accuracy Apparent dielectric permittivity (εa): ± 1 εa (unitless) from 1 – 40 (soil range), ± 15% from 40 – 80

Soil Volumetric Water Content (VWC): using Topp equation: ± 0.03 m3/m3 (± 3% VWC) typical in mineral soils that have solution electrical conductivity < 10 dS/m; using medium specific calibration, ± 0.01 - 0.02 m3/m3(± 1 – 2% VWC) in any porous medium

Electrical conductivity (EC): ± 10% from 0 to 7 dS/m, user calibration required above 7 dS/m

Temperature: ± 1 °C

Resolution εa: 0.1 εa (unitless) from 1 – 20, < 0.75 εa (unitless) from 20 – 80

VWC: 0.0008 m3/m3 (0.08% VWC) from 0 to 50% VWC

EC: 0.01 dS/m from 0 to 7 dS/m, 0.05 dS/m from 7 to 23.1 dS/m

Temperature: 0.1 °C

Range εa: 1 (air) to 80 (water)

EC: 0 – 23 dS/m (bulk)

Temperature: -40 to 60 °C*

*Sensors can be used at higher temperatures under some conditions

Measurement time 150 ms
Sensor type VWC: frequency domain

EC: two-probe design

Temperature: thermistor

Output RS232 (TTL), or SDI-12
Operating environment 40 to 60 °C*

*Sensors can be used at higher temperatures under some conditions. Contact METER for more details.

Power requirements 3.6 – 15 VDC, 0.3 mA quiescent, 10 mA during 150 ms measurement
Cable length Sensors come standard with 5 m cable. Custom cable lengths available. Maximum cable length of 75 m. Please contact METER if you need longer cable lengths.
Cable connector types 3.5 mm “stereo” plug or stripped and tinned lead wires (3)
Dimensions 10 cm x 3.2 cm x 0.7 cm
Data logger compatibility (not exclusive) METER Em50/50GEM60/60GProCheck, Campbell Scientific
Measurement volume See comparison article
Warranty One year, parts and labor