Thiesclima Compact Sensor

Description
Part number: 4.920x.00.00x
This instrument has a GPS receiver. It serves for the determination of position and time, the sun position is additionally calculated herefrom. Position, Time and sun position are transmitted serially.
The compact construction, easy mounting, and diverse options of data output are the basis for the use in several fields:
Building control system
Traffic engineering
Meteorology
Energy supply
Ecological monitoring
Specification
Part number: 4.920x.00.00x
Wind speed | |
Measuring range | 0 … 60 m/s |
Resolution | 0.1 m/s ( standard ) |
Accuracy | ±0.3 m/s rms ( < 5 m/s )
±3 % rms ( 5 m/s ... 60 m/s ) |
Wind direction | |
Measuring range | 0 … 360 ° |
Resolution | 1 ° 0.1 ° in special telegrams |
Accuracy | ±2 ° WS > 2 m/s |
Virtual temp. | |
Measuring range | -40 … +80 °C |
Resolution | 0.1 K |
Accuracy | ±0.5 K |
Data output digital | |
Interface | RS485 / RS422 |
Baudrate | 1200 … 921600 Baud |
Data values | div. meas. data, date, time, check sum etc. |
Output range | 1 per 10 msec up to 1 per 60sec |
Status signals | heating, Meas section error, Temperature of meas section |
Protocol | ASCII ( preselected ) |
Data output analog | |
Type | max. 8 x 0 … 10 V |
Wind speed | 0 … 10 V |
Stromausgang | max. 400 Ω |
Wind direction | 0 … 10 V |
Voltage output | min. 2000 Ω |
Output parameters | wind speed, wind direction, brightness, precipitation, rel. humidity, air temperature, air pressure , etc. |
Operating voltage | |
Electronic | 6 … 60V DC or 10 … 42 V AC / 1.2 W |
Heating | 24 V AC/DC, typ 25W |
General | |
Bus operation | up to 98 sensors |
Electr. connection | 19 pol. connector |
Mounting | on a mast tube 1,5“ |
Housing | Plastic LEXAN (Polycarbonat, UV-stabilised) |
Protection | IP 67 |
Versions
As per 4.920x.00.00x, but:
Product number 4.9200.00.000
Precipitation | |
Measuring range | 0.001 … 10 mm/min |
Temperature | |
Measuring range | -40 … +80 °C |
Accuracy | ±0,3 K ( @ 25 °C ) |
Rel. Humidity | |
Measuring range | 0 … 100 % rel. h. |
Accuracy | ± 1.8 % rel. h. ( 10 % … 90 % rel. H. ) |
Brightness | |
Measuring range | 0 … 150 kLux |
Accuracy | 3 % vom rel. Messwert |
Air pressure | |
Measuring range | 300 … 1100 hPa |
Accuracy | ±0.25 hPa ( +10 °C … +35 °C ) |
Data output analog | |
Output parameters | wind speed, wind direction, brightness, precipitation, rel. humidity, air temperature, air pressure , etc. |
General | |
Dimension | Ø 150 x 220 mm |
Weight | 0.9 kg |
Product number 4.9200.00.001
Precipitation | |
Measuring range | 0.001 … 10 mm/min |
Temperature | |
Measuring range | -40 … +80 °C |
Accuracy | ±0,3 K ( @ 25 °C ) |
Rel. Humidity | |
Measuring range | 0 … 100 % rel. h. |
Accuracy | ± 1.8 % rel. h. ( 10 % … 90 % rel. H. ) |
Brightness | |
Measuring range | 0 … 150 kLux |
Accuracy | 3 % vom rel. Messwert |
Air pressure | |
Measuring range | 300 … 1100 hPa |
Accuracy | ±0.25 hPa ( +10 °C … +35 °C ) |
Data output digital | |
Protocol | MODBUS RTU ( preselected ) |
Data output analog | |
Output parameters | wind speed, wind direction, brightness, precipitation, rel. humidity, air temperature, air pressure , etc. |
General | |
Dimension | Ø 150 x 220 mm |
Weight | 0.9 kg |
Product number 4.9201.00.000
Temperature | |
Measuring range | -40 … +80 °C |
Accuracy | ±0,3 K ( @ 25 °C ) |
Rel. Humidity | |
Measuring range | 0 … 100 % rel. h. |
Accuracy | ± 1.8 % rel. h. ( 10 % … 90 % rel. H. ) |
Air pressure | |
Measuring range | 300 … 1100 hPa |
Accuracy | ±0.25 hPa ( +10 °C … +35 °C ) |
Data output analog | |
Output parameters | wind speed, wind direction, rel. humidity, air temperature, air pressure , etc. |
General | |
Dimension | Ø 150 x 220 mm |
Weight | 0.9 kg |
Product number 4.9201.00.001
Temperature | |
Measuring range | -40 … +80 °C |
Accuracy | ±0,3 K ( @ 25 °C ) |
Rel. Humidity | |
Measuring range | 0 … 100 % rel. h. |
Accuracy | ± 1.8 % rel. h. ( 10 % … 90 % rel. H. ) |
Air pressure | |
Measuring range | 300 … 1100 hPa |
Accuracy | ±0.25 hPa ( +10 °C … +35 °C ) |
Data output digital | |
Protocol | MODBUS RTU ( preselected ) |
Data output analog | |
Output parameters | wind speed, wind direction, rel. humidity, air temperature, air pressure , etc. |
General | |
Dimension | Ø 150 x 220 mm |
Weight | 0.9 kg |
Product number 4.9202.00.000
Precipitation | |
Measuring range | 0.001 … 10 mm/min |
Brightness | |
Measuring range | 0 … 150 kLux |
Accuracy | 3 % vom rel. Messwert |
Data output analog | |
Output parameters | wind speed, wind direction, brightness, precipitation, etc. |
General | |
Dimension | Ø 150 x 175 mm |
Weight | 0.7 kg |
Product number 4.9202.00.001
Precipitation | |
Measuring range | 0.001 … 10 mm/min |
Brightness | |
Measuring range | 0 … 150 kLux |
Accuracy | 3 % vom rel. Messwert |
Data output digital | |
Protocol | MODBUS RTU ( preselected ) |
Data output analog | |
Output parameters | wind speed, wind direction, brightness, precipitation, etc. |
General | |
Dimension | Ø 150 x 175 mm |
Weight | 0.7 kg |
Product number 4.9203.00.000
Data output analog | |
Output parameters | wind speed, wind direction, etc. |
General | |
Dimension | Ø 150 x 175 mm |
Weight | 0.7 kg |
Product number 4.9203.00.001
Data output digital | |
Protocol | MODBUS RTU ( preselected ) |
Data output analog | |
Output parameters | wind speed, wind direction, etc. |
General | |
Dimension | Ø 150 x 175 mm |
Weight | 0.7 kg |